Southern Analytical process analyzers, process monitors and instrumentation for on-line, in-situ and at-line measurement systems, providing continuous single or multicomponent concentration. Techniques employed include: photometric (use of discrete photometers), spectrophotometric (using full spectrum spectrometer), FTIR (FT-IR), FT-NIR, photodiode array (diode array or PDA) UV/VIS (or alternatively single region NIR, UV or VIS), NIR, Mass Spectrometers, tunable diode laser/lasers (TDL) and more... These systems are applied in: polymer melt monitoring for additives; density and other properties; sulfur (sulphur) recovery unit (SRU) tail gas analyzers (air demand and ratio analyzers); Claus, Modified Claus and Superclaus process plant control; amine based tail gas treaters (TGTUs); low-level moisture analyzers; quality of natural gas for moisture, H2S, hydrocarbon dew point (dewpoint); and, gas, liquid, solids composition analysis. Southern Analytical can provide complete integrated analyzers and process control monitors with sampling systems, analyzer enclosures (wall mounting enclosure, shelter or house) and output for plant process control. We offer analyzers for: H2S (hydrogen sulfide), SO2 (sulfur dioxide), COS, CS2, , NO, NO2, NOx, Cl2 (chlorine), chlorine dioxide, NH3, ammonia, BTX, BTEX, benzene, toluene, xylene, aromatics, CO, CO2, color, Saybolt color, Tag Robinson color, APHA color, ASTM color, ASTM 1500 color, Hazen color, Platinum Cobalt color, Sulfur vapor, total sulfur, MEHQ, TBC, H2O, moisture, HRVOC, VOCs, Oxygen (O2) and trace impurities. Our process analyzers have been used for measurements in Refineries, Power Plants, Chemical and Petrochemical plants for process quality, control, as well as continuous emissions monitoring (CEM or CEMs)...
Southern Analytical
Home Applicaton Inquiry Products
Contact Us
Southern Analytical Inc.
Ametek Analyzers
Borreal Laser Inc. gasfinders
Bruker Optiks spectroscopy
Det-Tronics flame and gas
Moisture Register Products analysis
Optical Contol Systems polymer
Southern Analytical Inc.

Southern Analytical, Inc.
19407 Oil Center Boulevard
Houston, Texas 77073

Phone: (281) 591-0800
Fax: (281) 591-0052

Toll-Free: (888) 591-6300

Sitemap
Analyzer and Integrated Systems

<< Back

Sour Gas Processing and Conditioning

Model 933-C Reliable H2S Analyzer for the Contactor Overhead

A critical measurement of natural gas quality is the concentration of hydrogen sulfide (H2S). Remarkably, the common technique for making this measurement, lead acetate tape, is at least 70 years old. Use of this archaic technology requires that the sample gas be relatively free of moisture or dry. These analyzers must be installed, not on the outlet of the sweetening process they are meant to control, but far downstream—after the dryers.



Model 4650 H2S in Lean Amine Analyzer

Amine regeneration costs consume massive amounts of energy, much wasted due to over-stripping. Energy use can be dramatically minimized by accurate and reliable analysis of the residual H2S in lean amine.



Model 4660 Low Concentration H2S Analyzer

The need for the measurement of low level H2S in sales gas is important both for corrosion control and personal safety. Reducing the level excessively to provide safety margin drastically increases the operating costs of removal and recovery operation whereas high levels of H2S will result in costly plant shutdowns.



Model 4670 H2S in Rich Amine Analyzer

Substantial energy savings can be achieved in amine regeneration by controlling amine recirculation to ensure optimum H2S loading. Continuous measurement of the H2S in rich amine permits feedback control to the circulator thus ensuring optimum absorber efficiency.